{"id":1164,"date":"2026-04-13T12:36:31","date_gmt":"2026-04-13T03:36:31","guid":{"rendered":"https:\/\/acoustic-measurement.com\/?post_type=technology&#038;p=1164"},"modified":"2026-04-13T12:37:18","modified_gmt":"2026-04-13T03:37:18","slug":"streamlining-field-measurements-and-material-assessment","status":"publish","type":"technology","link":"https:\/\/acoustic-measurement.com\/en\/technology\/streamlining-field-measurements-and-material-assessment\/","title":{"rendered":"Evaluation Methods in Building Acoustics: Streamlining Field Measurements and Material Assessment in Laboratory Environments"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n\n\n<p>Accurate evaluation and design in building acoustics\u2014such as airborne sound insulation, floor impact sound, and reverberation time\u2014require two complementary elements: on-site measurements using a standards-compliant system capable of operating reliably under challenging field conditions (HBK), and highly precise baseline data obtained in a reproducible acoustic test environment (SONORA).<\/p>\n\n\n\n<p>At Moritani &amp; Co., Ltd., we integrate the systems of these two leading manufacturers\u2014one specializing in measurement instrumentation and the other in acoustic test facilities\u2014to provide a one-stop acoustic quality assurance solution, from building material development through to post-completion performance evaluation of real spaces.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Background and Rationale<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Challenges of On-Site Evaluation and How HBK Addresses Them<\/h3>\n\n\n\n<p>In sound insulation measurements conducted on construction sites under standards such as ISO 16283 and ISO 140, there are many practical hurdles, including background noise, dust, and the need to move between measurement points such as the source room and the receiving room. HBK\u2019s Building Acoustic Partner system\u2014consisting of the 2255 Sound Level Meter, 2755 Smart Power Amplifier, and an omnidirectional sound source\u2014dramatically improves field workflows through app-based automation and synchronized dual-device measurements of L1 (source room) and L2 (receiving room).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Free-Field Conditions in the Laboratory and SONORA\u2019s Technology<\/h3>\n\n\n\n<p>On the other hand, comparative evaluation of a building material panel itself\u2014such as its sound transmission loss or absorption coefficient\u2014requires a disturbance-free laboratory environment. In SONORA\u2019s anechoic test facilities, including the <strong>MFAC (Modular Fully-Anechoic Chamber)<\/strong>, the test environment is designed based on <strong>ISO 3745:2012<\/strong>, with strong emphasis on achieving a free-field condition demonstrated by an environmental correction value of <strong>K2 \u2264 0.5 dB<\/strong>.<\/p>\n\n\n\n<p>Since Annex K of the former <strong>ISO 3745:2003<\/strong> has been removed, evaluation of the sound field can no longer rely simply on absorber material type or wedge length. Instead, reliable data acquisition now depends on performance-based verification\u2014specifically, confirming whether the <strong>inverse square law<\/strong> is actually satisfied in the space.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure and Practical Example: Workflow for Building Acoustic Measurements<\/h2>\n\n\n\n<p>The following workflow illustrates how building acoustic evaluation can be carried out efficiently in practice using the HBK system.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Measurement Planning (App Integration)<\/h3>\n\n\n\n<p>Using the HBK mobile app, the user sets the measurement target\u2014such as a partition wall, floor, or external wall\u2014and selects the applicable standard. Measurement points can also be predefined in advance.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Sound Source Placement and Setup<\/h3>\n\n\n\n<p>An omnidirectional sound source and the HBK 2755 amplifier are installed in the source room (<strong>L1<\/strong>). Noise generation can then be controlled and optimized wirelessly via the app.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><a><\/a>Synchronized Measurement of Sound Pressure Level and Reverberation Time<\/h3>\n\n\n\n<p>Two HBK 2255 units are connected to the app, allowing simultaneous measurement of sound pressure levels in the source room (<strong>L1<\/strong>) and receiving room (<strong>L2<\/strong>). Even when performed by a single operator, this greatly reduces the time required to move between rooms.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><a><\/a>Data Analysis and Report Generation<\/h3>\n\n\n\n<p>The measurement data are synchronized to a PC and automatically analyzed by the software. A standards-compliant report can then be generated with a single click.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Comparison: Distinct Roles of Field Measurement and Laboratory Evaluation<\/h2>\n\n\n\n<p>Proper use depends on the objective and project phase, and it is important to establish a workflow that links both approaches effectively.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Field Measurement (HBK Building Acoustics Solution)<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><th>Primary purpose<\/th><td>Verification of overall sound insulation performance and room acoustics in actual buildings<\/td><\/tr><tr><th>Typical spaces<\/th><td>Apartments, offices, halls, and other buildings before or after completion<\/td><\/tr><tr><th>Example equipment<\/th><td>HBK 2255, 2755 amplifier, omnidirectional sound source<\/td><\/tr><tr><th>Acoustic conditions<\/th><td>Real-world environments, including the effects of background noise and flanking transmission<\/td><\/tr><tr><th>Advantages<\/th><td>Direct confirmation of actual acoustic performance under real operating and occupancy conditions<\/td><\/tr><tr><th>Limitations \/ points of attention<\/th><td>Highly susceptible to flanking transmission, making it difficult to isolate the intrinsic performance of an individual wall element<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Laboratory Evaluation (SONORA Acoustic Test Facilities)<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><th>Primary purpose<\/th><td>Precise evaluation of sound absorption coefficient, sound transmission loss, and sound power level of individual building materials and products<\/td><\/tr><tr><th>Typical spaces<\/th><td>Anechoic chambers (MFAC \/ VSAC), semi-anechoic chambers (MSAC), sound transmission loss test rooms, and related facilities<\/td><\/tr><tr><th>Example equipment<\/th><td>HBK acoustic measurement systems combined with SONORA acoustic test facilities<\/td><\/tr><tr><th>Acoustic conditions<\/th><td>Controlled sound field environment<br>(<strong>K2 correction value \u2264 0.5 dB<\/strong>, inverse square law confirmed)<\/td><\/tr><tr><th>Advantages<\/th><td>Enables external noise to be eliminated, allowing pure comparative assessment against other materials and supporting product development<\/td><\/tr><tr><th>Limitations \/ points of attention<\/th><td>Cannot fully reproduce actual installation conditions, such as site-specific gaps, joints, or detailing<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Key Takeaways<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><th>Optimization of field measurements<\/th><td>HBK\u2019s dedicated building acoustics solution dramatically reduces both labor and human error in difficult on-site measurement environments.<\/td><\/tr><tr><th>Reliability of laboratory evaluation<\/th><td>Precise acoustic assessment of building materials requires SONORA\u2019s test facilities, designed to meet current standards such as <strong>ISO 3745:2012<\/strong>.<\/td><\/tr><tr><th>Total support from Moritani<\/th><td>From building accurate laboratory environments for material evaluation (<strong>SONORA<\/strong>) to implementing high-efficiency field measurement systems (<strong>HBK<\/strong>), as well as integrating both into a complete acoustic evaluation solution, Moritani provides comprehensive support through a single point of contact.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Contact<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Inquiries regarding demo unit rentals for HBK products<\/li>\n\n\n\n<li>Budgetary cost estimates and layout proposals for SONORA anechoic chambers (including MFAC) and sound insulation facilities<\/li>\n\n\n\n<li>Support for introducing integrated acoustic evaluation solutions combining both systems<\/li>\n<\/ul>\n\n\n\n<p>\u25b6 <strong>[<a href=\"https:\/\/acoustic-measurement.com\/en\/contact\/\">Contact Us Here<\/a>]<\/strong><\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Conclusion Accurate evaluation and design in building acoustics\u2014such as airborne sound insulation, floor impact sound, and reverberation time\u2014require two complementary elements: on-site measurements using a standards-compliant system capable of operating reliably under challenging field conditions (HBK), and highly precise baseline data obtained in a reproducible acoustic test environment (SONORA). At Moritani &amp; Co., Ltd., we [&hellip;]<\/p>\n","protected":false},"featured_media":1163,"parent":0,"template":"","solution_cat":[2],"class_list":["post-1164","technology","type-technology","status-publish","has-post-thumbnail","hentry","solution_cat-tax_power","en-US"],"acf":[],"_links":{"self":[{"href":"https:\/\/acoustic-measurement.com\/wp-json\/wp\/v2\/technology\/1164","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/acoustic-measurement.com\/wp-json\/wp\/v2\/technology"}],"about":[{"href":"https:\/\/acoustic-measurement.com\/wp-json\/wp\/v2\/types\/technology"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/acoustic-measurement.com\/wp-json\/wp\/v2\/media\/1163"}],"wp:attachment":[{"href":"https:\/\/acoustic-measurement.com\/wp-json\/wp\/v2\/media?parent=1164"}],"wp:term":[{"taxonomy":"solution_cat","embeddable":true,"href":"https:\/\/acoustic-measurement.com\/wp-json\/wp\/v2\/solution_cat?post=1164"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}